| Attribute name | Attribute value |
|---|---|
| Main | |
| Device application | equipment monitoring and control |
| Relative humidity | 0-93 % non-condensing |
| Output current | <= 7 A |
| Ambient air temperature for storage | -10-85 °C |
| Colour | black |
| Directives | 2014/35/EU - low voltage directive, 2014/30/EU - electromagnetic compatibility |
| Function available | firmware update |
| Range | EcoStruxure Security Expert |
| Input/output type | 8 form C relay output |
| Ambient air temperature for operation | 0-50 °C |
| Height | 60 mm |
| Width | 90 mm |
| [In] rated current | 80 mA |
| Net weight | 428 g |
| Product or component type | output module |
| Product brand | Schneider Electric |
| Product certifications | ACMA, CE |
| Complementary | |
| Maximum supply current | 3.25 A |
| Environmental characteristic | indoor use |
| Standards | CAN/ULC-S319-05, UL 294, ICES-003 class A, FCC CFR 47 part 15: class A, CAN/ULC-S559-04, CAN/ULC-S304-06, UL 1610, EN 50131-6:2008, EN 50131-3:2009, EN 50131-1:2006 |
| Quality labels | RCM |
| Local signalling | 8 LED (red) for output status, 1 LED (red) for fault, 1 LED (green/red) for status, 1 LED (green) for power |
| Range compatibility | EcoStruxure Security Expert controller |
| Mounting support | DIN rail |
| Output current limits | 1.1 A |
| Output voltage | 10.83...14 V DC,0.7 A |