| Attribute name | Attribute value |
|---|---|
| Main | |
| Metering type | calculated active and reactive energy (+/- W.h, +/- VAR.h), peak demand power PM, QM, SM, demand power P, Q, S, peak demand currents, demand current I1, I2, I3, I4, I5 |
| Device short name | ION95030 |
| Device application | high voltage, medium voltage, Net metering, WAGES metering, power monitoring |
| Range | PowerLogic |
| Product name | PowerLogic ION9000 |
| Product or component type | energy and power quality meter |
| Complementary | |
| Display type | without display |
| Web services | push historical data via mail, TLS 1.2, alarm notification by e-mail, NEMA motor derating curve, SEMI curve, ITIC (CBEMA) curve, pass/fail report for EN 50160, pass/fail report for IEEE 519, web page, viewing of captured waveform |
| Measurement accuracy | current +/- 0.1 %, voltage +/- 0.1 % |
| Electrical insulation class | class III conforming to EN/IEC 62052-11 |
| Frequency measurement range | 20-450 Hz |
| Communication service | SNMP, SMTP e-mail notification, EcoStruxure Power Events Analysis, energy report, power quality summary, compliant reports |
| Communication port protocol | DLMS, DNS, DHCP, Ethernet Modbus TCP/IP daisy chain at 10/100 Mbit/s, IEC 61850, DNP3 TCP at 10/100 Mbit/s, ION TCP at 10/100 Mbit/s, Modbus TCP at 10/100 Mbit/s, DNP3 at 2400...115200 bps - 2-wire, ION at 2400...115200 bps - 2-wire, Modbus RTU at 2400...115200 bps - 2-wire |
| Type of measurement | harmonic distorsion (I THD & U THD), apparent energy, active and reactive energy, power factor per phase, power factor total, apparent power per phase, active and reactive power per phase, apparent power total, active and reactive power total, frequency, current, voltage, current sags and swells, voltage sags and swells |
| Memory capacity | 2 GB |
| Height | 160 mm |
| Power quality analysis | transient detection (100 ns), coincidence disturbance waveform capture, high-speed transient capture, half cycle data acquisition, dip, swell and transient, disturbance direction detection, up to the 127th harmonic with software, up to the 63rd harmonic, total harmonic distortion, total demand distortion, waveform capture, conforming to IEEE 519 compliance reporting, conforming to IEC 61000-4-30: class A compliance reporting, conforming to IEEE 519 harmonic limit, EN 50160 compliance checking |
| Communication port support | RS485 2 removable screw terminal block |
| [Us] rated supply voltage | 110...480 V DC +/- 15 %, 90...120 V AC 400 Hz +/- 10 %, 90...480 V AC 45...66 Hz +/- 10 % |
| Maximum power consumption in VA | 80 VA at 480 V AC |
| Accuracy class | class 0.5 power factor conforming to IEC 61557-12, class 0.1 active power conforming to IEC 61557-12, class 0.1 voltage conforming to IEC 61557-12, class 0.1 current conforming to IEC 61557-12, class 0.5S reactive energy conforming to IEC 62053-24, class 0.1 active energy conforming to ANSI C12.20, class 0.1 active energy conforming to IEC 61557-12, class 0.1S active energy conforming to IEC 62053-22 |
| Depth | 135.3 mm |
| Market segment | mining, energy, chemical, pharmaceutical, semiconductor, healthcare, data center |
| Width | 160 mm |
| Analogue input type | external CT (impedance 0.3 mOhm)5 x , voltage (impedance 5 MOhm) |
| Isolation voltage | III347-600 V conforming to CSA C22.2 No 61010-1:ed. 3, III347-600 V conforming to UL 61010-1:ed. 3, III400-690 V conforming to EN 61010-1:ed. 3 |
| Cybersecurity | hardware metrology lock, enable/disable communication ports, port hardening, robust security logs, Syslog protocol support |
| [In] rated current | 5 A, 1 A |
| Data recording | sequence of event recording, GPS synchronisation, data logs, user login/logout, power outage, configuration change, alarm logs, event logs, trending/forecasting, continuous logging or snapshot, user-definable data logs, min/max of instantaneous values, time stamping |
| Poles description | 3P + N + E |
| Communication gateway | Ethernet/serial |
| Mounting support | DIN rail |
| Ethernet service | FTP/HTTP/HTTPS, Rapid Scanning Tree Protocol (RSTP), Device Profile Web Services (DPWS), DHCP client |
| Time synchronisation protocol | PTP, SNTP, NTP, IRIG-B, GPS |
| Number of inputs | 8 digital 30 V AC/60 V DC |
| Measurement current | 0.01-20 A |
| Tamperproof of settings | protected by sealable cover |
| Net weight | 1.5 kg |
| Power consumption in VA | 38 VA at 480 V AC |
| Port Ethernet | 10/100BASE-TX 2 RJ45 |
| Ride-through time | 1200 ms 72 cycles at 60 Hz 480 V AC typical, 400 ms 24 cycles at 60 Hz 240 V AC typical, 100 ms 6 cycles at 60 Hz 120 V AC typical |
| Number of outputs | 2 form C relay, 4 digital |
| Sampling rate | 1024 samples/cycle |
| Measurement voltage | 10-10 kV AC transient, 100-690 V AC 42...69 Hz between phases, 57-400 V AC 42...69 Hz between phase and neutral |
| Network frequency | 60 Hz, 50 Hz |
| Environment | |
| IP degree of protection | IP30 rear: , IP65 front: |
| Relative humidity | 5-95 % |
| Ambient air temperature for storage | -40-85 °C |
| Electromagnetic compatibility | surge withstand conforming to IEEE C37.90.1, surge withstand conforming to ANSI C37.90.1, conducted and radiated emissions class B conforming to ICES-003, conducted and radiated emissions class B conforming to FCC part 15, conducted and radiated emissions class B conforming to EN 55032, conducted and radiated emissions conforming to EN 55011, immunity to impulse waves conforming to IEC 61000-4-12, voltage dips and interruptions immunity test conforming to IEC 61000-4-11, immunity to conducted disturbances - test level: 2...150 kHz conforming to CLC/TR 50579, immunity to magnetic fields at network frequency conforming to IEC 61000-4-8, immunity to conducted disturbances conforming to IEC 61000-4-6, surge immunity test conforming to IEC 61000-4-5, immunity to fast transients conforming to IEC 61000-4-4, immunity to radiated fields conforming to IEC 61000-4-3, electrostatic discharge immunity test conforming to IEC 61000-4-2, EMC immunity conforming to IEC 61000-6-5, EMC immunity conforming to IEC 61326-1, EMC immunity conforming to IEC 62052-11 |
| Degree of protection | UL type 12, front |
| Standards | UL 61010-1, IEC 62586, IEC 62053-24, IEC 62053-23, IEC 62053-22, IEC 62052-31, IEC 62052-11, IEC 61850, IEC 61557-12, IEC 61326-1, IEC 61010-1, IEC 61000-4-30, IEC 61000-4-15, ANSI C37.90.1, ANSI C12.20 |
| Ambient air temperature for operation | -25-70 °C |
| Installation category | III |
| Operating altitude | 0...3000 m |
| Quality labels | ISO 14000, ISO 9001 |