Don't have an account?
| Attribute name | Attribute value |
|---|---|
| Main | |
| Device short name | LTMR |
| Device application | equipment monitoring and control |
| Supply voltage limits | 20.4-26.24 V DC |
| Bus type | CANopen ISO 1198 interface, addressing 1...127, transmission rate 10...1000 kbit/s, terminal block with 4 twisted shielded pairs cable, CANopen ISO 1198 interface, addressing 1...127, transmission rate 10...1000 kbit/s, SUB-D 9 with 4 twisted shielded pairs cable |
| Communication port protocol | CANopen |
| [Us] rated supply voltage | 24 V DC |
| Current consumption | 56...127 mA |
| Range | TeSys |
| Measurement current | 5-100 A |
| Product name | TeSys T |
| Product or component type | motor controller |
| Complementary | |
| Metering type | average current Iavg, phase current I1, I2, I3 RMS, temperature, earth-fault current, imbalance current |
| Maximum operating frequency | 2 Hz |
| Depth | 122.5 mm |
| Tightening torque | control circuit: 0.5-0.6 N.m flat screwdriver 3 mm |
| Overvoltage category | III |
| Load current | 5 A at 30 V DC for logic output, 5 A at 250 V AC for logic output |
| Width | 91 mm |
| Web services | web server |
| Protection type | overload, locked rotor, earth-leakage protection, power factor variation, load fluctuation, thermal overload protection, overload (long time), phase failure, phase unbalance, reverse polarity protection, thermal protection |
| Compatibility code | LTMR |
| Short-circuit withstand | 100 kA conforming to EN/IEC 60947-4-1 |
| [Ui] rated insulation voltage | 690 V conforming to UL 508, 690 V conforming to CSA C22.2 No 14, 690 V conforming to EN/IEC 60947-1 |
| Current state 0 guaranteed | logic input: < 5 V and <= 15 mA for 5 ms |
| Measurement accuracy | 0,02 current, 5 % active and reactive power, 0,02 temperature, +/- 30 min/year internal clock, 5 % earth fault current external measurement, 3 % power factor, 1 % voltage (100...830 V), 5...15 % earth fault current internal measurement |
| Electromagnetic compatibility | control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5, temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5, temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5, conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6, voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11, fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4, fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4, radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3, relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5, relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5, communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5, control circuit: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5, electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 |
| Associated fuse rating | 0.5 A gG for control circuit, 4 A gG for output |
| [Uimp] rated impulse withstand voltage | 0.8 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1, 0.8 kV communication circuit conforming to EN/IEC 60947-4-1, 6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1 |
| Net weight | 0.53 kg |
| Current state 1 guaranteed | logic input: < 15 V and 2...15 mA for 15 ms |
| Input current | 7 mA |
| Connections - terminals | control circuit: connector 2 cable(s) 0.2-1 mm² (AWG 24...AWG 14) solid without cable end, control circuit: connector 2 cable(s) 0.5-1.5 mm² (AWG 24...AWG 14) flexible without cable end, control circuit: connector 2 cable(s) 0.2-1.5 mm² (AWG 24...AWG 14) flexible without cable end, control circuit: connector 2 cable(s) 0.2-1 mm² (AWG 24...AWG 14) flexible with cable end, control circuit: connector 1 cable(s) 0.2-2.5 mm² (AWG 24...AWG 14) solid without cable end, control circuit: connector 1 cable(s) 0.25-2.5 mm² (AWG 24...AWG 14) flexible without cable end, control circuit: connector 1 cable(s) 0.2-2.5 mm² (AWG 24...AWG 14) flexible without cable end, control circuit: connector 1 cable(s) 0.25-2.5 mm² (AWG 24...AWG 14) flexible with cable end |
| Maximum operating rate | 1800 cyc/h |
| Logic input number | 6 |
| Pollution degree | 3 |
| Network and machine diagnosis type | trip history information, running hours counter/operating time, waiting time after overload tripping, phase fault and earth fault trip counters, remaining operating time before overload tripping, fault recording, event recording, starting current and time, trip context information, motor control command recording |
| Permissible power | 30 W (DC-13), Ie = 1.25 A, 500000 cycles (output), 480 VA (AC-15), Ie = 2 A, 500000 cycles (output) |
| Connection pitch | 5.08 mm |
| Height | 61 mm |
| Contacts type and composition | 3 NO, 1 NO + 1 NC fault signal |
| Environment | |
| IP degree of protection | IP20 |
| Fire resistance | 960 °C conforming to UL 94, 650 °C conforming to EN/IEC 60695-2-12 |
| Operating altitude | <= 2000 m without derating |
| Protective treatment | TH conforming to EN/IEC 60068, 48 h conforming to EN/IEC 60070-2-11, 12 x 24 hour cycles conforming to EN/IEC 60068-2-30 |
| Ambient air temperature for storage | -40-80 °C |
| Standards | EN 60947-4-1, IEC 60947-4-1, UL 508, CSA C22.2 No 14, IACS E10 |
| Ambient air temperature for operation | -20-60 °C |
| Mechanical robustness | shocks half sine wave acceleration: 15 Gn for 11 ms conforming to EN/IEC 60068-2-27, vibrations plate mounted: 4 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6, vibrations mounted on symmetrical rail: 1 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6 |
| Product certifications | DNV, BV, GL, CSA, LROS (Lloyds register of shipping), RMRoS, NOM, UL, ATEX, EAC, KERI, RINA, ABS, C-Tick, CCC |