| Attribute name | Attribute value |
|---|---|
| Main | |
| Discrete I/O processor capacity | 704 I/O single-rack configuration, 1024 I/O multi-rack configuration |
| Number of application specific channel | 36 |
| Number of slots | 11 |
| Number of racks | 4 |
| Range of product | Modicon M340 automation platform |
| Monitoring | event counters Modbus, diagnostic counters Modbus |
| Analogue I/O processor capacity | 66 I/O single-rack configuration, 256 I/O multi-rack configuration |
| Product or component type | processor module |
| Complementary | |
| Control channels | programmable loops |
| Memory description | internal RAM 3584 kB program constants and symbols, internal RAM 256 kB data, internal RAM 4096 kB, supplied memory card (BMXRMS008MP) backup of programs, constants, symbols and data |
| Bus length | 0-15 m Modbus point-to-point, 0-15 m character mode point-to-point, 0-1000 m serial link isolated Modbus segment, 0-1000 m serial link isolated character mode segment, 0-10 m serial link non isolated Modbus segment, 0-10 m serial link non isolated character mode segment |
| Number of slave | 63 CANopen |
| Motion control | independent axis CANopen |
| Number of instructions per ms | 8.1 Kinst/ms 100 % Boolean, 6.4 Kinst/ms 65 % Boolean + 35 % fixed arithmetic |
| Bus type | CANopen M20 DS 405 devices linked by daisy-chaining or tap junctions CSMA/CA, CANopen M20 DS 303-2 devices linked by daisy-chaining or tap junctions CSMA/CA, CANopen M20 DS 301 V4.02 devices linked by daisy-chaining or tap junctions CSMA/CA |
| Number of devices | 2 point-to-point Modbus, 2 point-to-point character mode |
| Maximum tap links length | <40 m serial link isolated Modbus segment, <40 m serial link isolated character mode segment, <15 m serial link non isolated Modbus segment, <15 m serial link non isolated character mode segment |
| Application structure | 64 event tasks, 1 periodic fast task, 1 cyclic/periodic master task, no auxiliary task |
| Marking | CE |
| Transmission rate | 800 kbit/s 0-40 m 0-6 m, 500 kbit/s 0-100 m 0-10 m, 50 kbit/s 0-1000 m 0-120 m, 250 kbit/s 0-250 m 0-10 m, 20 kbit/s 0-2500 m 0-300 m, 125 kbit/s 0-500 m 0-10 m, 1 Mbit/s 0-20 m 0-0.6 m |
| Status LED | 1 LED (yellow) activity on Modbus (SER COM), 1 LED (red) processor or system fault (ERR), 1 LED (red) memory card fault (CARD ERR), 1 LED (red) integrated machine/installation bus fault (CAN ERR), 1 LED (red) I/O module fault (I/O), 1 LED (green) processor running (RUN), 1 LED (green) integrated machine/installation bus operational (CAN RUN) |
| Number of devices per segment | 0-64 for <160 m (CANopen), 0-32 for <185 m (CANopen), 0-16 for <205 m (CANopen), 0-32 (Modbus), 0-32 (character mode) |
| Number of addresses | 0-248 for Modbus, 0-248 for character mode |
| Control parameter | one LRC on each frame (ASCII) Modbus, one LRC on each frame (ASCII) character mode, one CRC on each frame (RTU) Modbus |
| Execution time per instruction | 1.16 µs floating points, 0.25 µs single-length words, 0.17 µs double-length words, 0.12 µs Boolean |
| Maximum size of object areas | 32634 %Mi located internal bits, 256 kB unlocated internal data |
| Communication service | special functions (SYNC, EMCY, TIME) CANopen, Service Data Object (SDO) CANopen, Process Data Object (PDO) CANopen, Network management (NMT) CANopen |
| System overhead | 0.7 ms for master task, 0.13 ms for fast task |
| Net weight | 0.21 kg |
| Current consumption | 90 mA at 24 V DC |
| Default size of object areas | 512 %Mi located internal bits, 256 %KWi constant words located internal data, 1024 %MWi internal words located internal data |
| Supply | internal power supply via rack |
| Requests | 504 data bytes per ASCII request Modbus, 252 data bytes per RTU request Modbus, 1 K data bytes per request character mode |
| Communication module processor capacity | 4 AS-Interface module, 2 Ethernet communication module |
| Integrated connection type | CANopen master bus SUB-D 9, transmission mode: 2 twisted shielded pairs at 20 kbit/s...1 Mbit/s, USB port at 12 Mbit/s, non isolated serial link RJ45, master/slave Modbus, RTU/ASCII, transmission mode: asynchronous in baseband, RS485, transmission mode: 1 twisted shielded pair at 0.3...19.2 kbit/s half duplex, non isolated serial link RJ45, master/slave Modbus, RTU/ASCII, transmission mode: asynchronous in baseband, RS232C, transmission mode: 1 twisted shielded pair at 0.3...19.2 kbit/s half duplex, non isolated serial link RJ45 character mode, transmission mode: asynchronous in baseband, RS485, transmission mode: 1 twisted shielded pair at 0.3...19.2 kbit/s half duplex, non isolated serial link RJ45 character mode, transmission mode: asynchronous in baseband, RS232C, transmission mode: 2 twisted shielded pairs at 0.3...19.2 kbit/s full duplex |
| Environment | |
| IP degree of protection | IP20 |
| Protective treatment | TC |
| Relative humidity | 10-95 % without condensation |
| Directives | 2014/30/EU - electromagnetic compatibility, 2014/35/EU - low voltage directive |
| Product certifications | Merchant Navy, EAC, RCM, CSA, UL, CE |
| Standards | EN/IEC 61850-3, location G, EN/IEC 61000-6-5, interface type 1 and type 2, IACS E10, CSA C22.2 No 61010-2-201, UL 61010-2-201, EN/IEC 61010-2-201, EN 61131-2 |
| Ambient air temperature for operation | 0-60 °C |
| Environmental characteristic | hazardous location class I division 2 |